Pressure, Level & Process
Hydrostatic Level / DP
Calculate hydrostatic pressure from liquid head and specific gravity, or determine the equivalent liquid head from a measured pressure.
Field use
Level transmitter range checks.
Useful for open-tank level, bubbler/reference checks and understanding the liquid-head contribution in DP level applications.
Calculation basis
P = ρ × g × h
ρ = SG × 1000 kg/m³
g = 9.80665 m/s²
ρ = SG × 1000 kg/m³
g = 9.80665 m/s²
Important: specific gravity and density vary with composition, temperature and pressure. For precision calibration or inventory work, use the actual process density at the required reference/operating condition.
This tool calculates liquid head only. It does not include vessel vapor pressure, capillary fill-fluid effects or remote-seal temperature effects.