Well Testing & Production
BS&W / Hydrocarbon Volume
Apply a stated basic sediment and water percentage to a measured liquid volume while keeping free-water treatment and all other correction factors explicit.
Production-test basis
BS&W is not automatically the same as water cut.
BS&W can include water, sediment and emulsion in the sampled production stream. Keep the laboratory/field measurement method and reporting basis with the result.
Calculation basis
BS&W volume = Basis × BS&W / 100
Hydrocarbon volume = Basis × (1 − BS&W / 100)
This is only a BS&W volume deduction. It does not apply temperature correction, pressure correction, shrinkage, meter factor, API gravity correction or convert separator-condition volume to stock-tank/standard volume. If free water is already represented by the stated BS&W measurement basis, leave the separate free-water field at zero to avoid double deduction.